You are here: Technical > Emergency Battery Options

Emergency Battery Options

Numerous fixtures in our catalog are available with Emergency Battery Options:
  • Integral Emergency Battery (EL)
  • Remote Emergency Battery (REL) - Verify Local Code Compliance.

The REL is a surface mount only, emergency ballast backup system. The REL option can be used in numerous types of luminaire installations. Download a copy of our Emergency Battery Options List which features illustrations that help demonstrate various mounting types and their associated REL applications as well as the options charts listed below.

Download: Emergency Battery Options

Emergency Battery Options Charts
Fluorescent Emergency Battery Pack
LED Emergency Circuit Options (AC)
LED Emergency Circuit Options (DC)
LED Emergency Battery Pack Options
► LED Integral Emergency Battery Pack Options 

FLUORESCENT EMERGENCY BATTERY PACKS
EL1 Integral Emergency Batter, Up to 600 Lumens, T8, 1 Lamp 17W-32W
Dimensions: 2.4" x 9.4" x 1.5"
EL2  Integral Emergency Battery, Up to 650 Lumens, DTT, TTT, 1-2 Lamps 6W-42W, 4PIN
Dimensions: 2.4" x 9.4" x 1.5"
EL7 Integral Emergency Battery, Up to 1400 Lumens, T8, DTT, TTT, 1 Lamp; 17W-215W; 2 Lamp 17W-40W; Dimensions: 2.4" x 13.3" x 1.5" 
EL9 Integral Emergency Battery, Up to 1400 Lumens, T8, DTT, TTT, 1 Lamp; 17W-215W; 2 Lamp 17W-40W; Dimensions: 2.4" x 13.4" x 1.5" 
 EL14 Integral Emergency Battery, Up to 750 Lumens, TT/DTT/TTT, 1 Lamp 13W-42W; 4PIN; Dimensions: 2.4" x 9.4" x 1.5" 
 EL31 Integral Emergency Battery, Up to 700 Lumens, T5, T5HO, T8, T8HO, 1 Lamp 14W-55W; Dimensions: 1.18" x 18.5" 1.18" 
 EL32 Integral Emergency Battery, Up to 1325 Lumens, T5, T5HO, T8, T8HO, 1 Lamp 14W-55W; Dimensions: 1.18" x 21.5" x 1.18" 
 EL35 Integral Emergency Battery, Cold Weather, Up to 1250 Lumens, TT/DTT/TTT, 1 Lamp 13W-42W; Dimensions: 2.6" x 9.4" x 1.5" 
 EL44 Integral Emergency Battery, Cold Weather, Up to 1300 Lumens, TT/DTT/TTT, 1 Lamp 13W-70W, 2 Lamps 13W-32W; Dimensions: 2.6" x 13.4" x 1.5"
 EL49 Integral Emergency Battery, Cold Weather, Up to 1200 Lumens, T8, 1 Lamp 17W-215W, 2 Lamps 17W-40W; Dimensions: 2.6" x 13.4" x 1.5" 
 EL52 Integral Emergency Battery, Cold Weather, Up to 1250 Lumens, TT/DTT/TTT, 1 Lamp 13W-70W, 2 Lamps 13W-32W; Dimensions: 5.5" x 6" x 1.6"
  ► Back to Top

LED EMERGENCY CIRCUIT OPTIONS (AC)
Emergency Circuit - onsite AC or DC emergency power circuit is provided
Onsite Emergency (AC) generator power is provided via a separate circuit to the fixture.
LED driver wired directly to 120VAC or 277VAC emergency power feed. No DC battery pack in fixture.
Two (2) AC power feeds exit the fixture. #1 Fixture AC power, #2 emergency AC power.
LED lamp/s are "ON" only during an emergency condition.
EC1A One (1) 5W LED Emergency Light. LED driver wired directly to 120VAC Emergency Power Feed.
EC2A  One (1) 5W LED Emergency Light. LED driver wired directly to 277VAC Emergency Power Feed.
EC3A Two (2) 5W LED Emergency Lights. LED driver wired directly to 120VAC Emergency Power Feed.
EC4A Two (2) 5W LED Emergency Lights. LED driver wired directly to 277VAC Emergency Power Feed.
 ECXA OTHER
  ► Back to Top

LED EMERGENCY CIRCUIT OPTIONS (DC)
Emergency Circuit - onsite AC or DC emergency power circuit is provided
Onsite Emergency (DC) battery power is provided via a separate circuit to the fixture.
LED driver wired directly to 12VDC or 24VDC emergency power feed. No DC battery pack in fixture.
Two (2) power feeds exit the fixture. #1 Fixture AC power, #2 emergency DC power.
LED lamp/s are "ON" only during an emergency condition.
EC1D One (1) 5W LED Emergency Light. LED light wired directly to 12VDC Emergency Power Feed.
EC2D  One (1) 5W LED Emergency Light. LED light wired directly to 24VDC Emergency Power Feed.
EC3D Two (2) 5W LED Emergency Lights. LED light wired directly to 12VDC Emergency Power Feed.
EC4D Two (2) 5W LED Emergency Lights. LED light wired directly to 24VDC Emergency Power Feed.
 ECXD OTHER
  ► Back to Top

LED EMERGENCY BATTERY PACK OPTIONS
Emergency Pack - NO onsite AC or DC emergency power circuit is provided
No onsite Emergency (AC or DC) power is provided via a separate circuit to the fixture.
LED light/s are wired directly to emergency battery pack in fixture. No LED driver used.
One (1) AC power feed exits the fixture.
LED lamp/s are "ON" only during an emergency condition.
EM1 One (1) 5W LED Emergency Light. LED light wired directly to Battery Pack. 120VAC Power Feed.
EM2  One (1) 5W LED Emergency Light. LED light wired directly to Battery Pack. 120VAC  Power Feed.
EM3 Two (2) 5W LED Emergency Lights. LED light wired directly to Battery Pack. 277VAC Power Feed.
EM4 Two (2) 5W LED Emergency Lights. LED light wired directly to Battery Pack. 277VAC Power Feed.
 EMX OTHER
  ► Back to Top

LED INTEGRAL EMERGENCY BATTERY PACK OPTIONS
Emergency Pack - NO onsite AC or DC emergency power circuit is provided
No onsite Emergency (AC or DC) power is provided via a separate circuit to the fixture.
LED light/s are wired directly to emergency battery packs LED Driver. One (1) AC power feed exits the fixture.
Emergency LED Lamp/s used are already a part of the fixture light source.
No additional emergency LED Lamp/s are installed inside fixture.
Emergency Wattage cannot exceed fixture wattage.
LED lamp/s used are "ON" constantly (24/7).
EL60 Integral Emergency Battery, LED 7W, Up to 420 Lumens (by IOTA). LED Driver Wired Directly to Battery Pack*
EL61 Integral Emergency Battery, LED 12W, Up to 720 Lumens (by IOTA). LED Driver Wired Directly to Battery Pack*
EL63 Integral Emergency Battery, LED 23W, Up to 1290 Lumens (by BODINE). LED Driver Wired Directly to Battery Pack*
EL67 Integral Emergency Battery, LED 23W, Up to 1290 Lumens (by IOTA). LED Driver Wired Directly to Battery Pack*
 EL69 Integral Emergency Battery, LED 23W, Up to 1290 Lumens (by IOTA). LED Driver Wired Directly to Battery Pack*
 EL82  Integral Emergency Battery, LED 4W, +/- 240 Lumens (by FULHAM). LED Driver Wired Directly to Battery Pack*
 EL83 Integral Emergency Battery, LED 20W, +/- 1200 Lumens (by FULHAM). LED Driver Wired Directly to Battery Pack* 
* Specify Fixture Voltage: 120V or 277V Power Feed: A=120V or B=277V (ie. EL67A - 120V; EL67B - 270V)
NOTE: Incorporating into Fixtures, Photocells, Motion Sensors, or Manual Switches may create additional Power Feeds exiting from the fixture. Also, additional site wiring may be required. 
  ► Back to Top